Motor cable short circuit / motor overcurrent
Short circuit of the motor cable, motor cable earth fault, or excessive capacitive charging current on a motor…
View cause & remedyTechnical reference
Causes and remedies for every error code, sourced from the official Lenze 9300 service manual (EDSVS9332S). Is your drive showing a specific code? Send us a photo — free diagnosis.
25 codes listed
Short circuit of the motor cable, motor cable earth fault, or excessive capacitive charging current on a motor…
View cause & remedyOne of the motor phases has earth contact.…
View cause & remedyFrequent or too long acceleration with overcurrent, or continuous overload with Imotor > 1.05 × Ir.…
View cause & remedyThe motor is continuously or repeatedly loaded above its rated current. OC8 is typically used as an advance wa…
View cause & remedyBraking energy is too high — the DC-bus voltage is higher than the value set in C0173.…
View cause & remedyThe DC-bus voltage is lower than the value set in C0173 — usually a faulty or dropping mains supply.…
View cause & remedyOne of the current-carrying motor phases has failed (open circuit).…
View cause & remedyAmbient temperature > +40 °C / +50 °C, very dirty heatsink, wrong mounting position, or the current limit is s…
View cause & remedyThe motor is thermally overloaded: impermissible continuous current or frequent/too long acceleration.…
View cause & remedyDirty heatsink, wrong mounting position, or the value set under C0122 is too low.…
View cause & remedyNo PTC/temperature contact connected, the value under C0121 is set too low, or the motor is thermally overload…
View cause & remedyFaulty or interrupted transfer of control commands via AIF — usually a loosely seated communication module/key…
View cause & remedyThe CAN_IN object receives faulty data or communication is interrupted — wiring, sender or interference on the…
View cause & remedyToo many faulty telegrams on the system bus (CAN) — bus termination, cable shielding or PE connection issues; …
View cause & remedyThe resolver cable is interrupted.…
View cause & remedyCable interrupted, pin X9/8 not connected, or the current signal at X6/1, X6/2 is < 2 mA.…
View cause & remedyThe absolute value encoder needs initialisation, the X8 cable is loose/broken, the encoder rotates during main…
View cause & remedyThe parameter set is corrupt or incompatible with the loaded software version (e.g. transferred from a higher-…
View cause & remedyError in the Drive PLC program flow.…
View cause & remedyInternal EEPROM fault — often after a sudden power loss or ageing EEPROM.…
View cause & remedyInternal control system failure (often triggered by strong EMC interference or a hardware fault).…
View cause & remedyThe sensor for detecting the heatsink / internal temperature is defective or its wiring is faulty.…
View cause & remedyThe angle difference between set and actual position is larger than allowed — insufficient torque, too-low gai…
View cause & remedyThe position exceeds the allowed angle limit — usually related to position limit parameters or a mechanical pr…
View cause & remedyInternal hardware fault in the memory or the power stage.…